(click above to return to home page)
INSPECTION REPORT
Inspector Information Eric Conrad-State of Arizona Certificate # 43658
|
Client Information |
|
|
REPORT CONFIDENTIALITYThis report is solely for the benefit of the Client. Any person or party designated by the Client to receive information in this report shall be subject to the TERMS AND CONDITIONS contained herein. Such designation shall be provided in writing to the inspector. |
REPORT SUMMARY (back to top) |
|
| Site Grounds and Grading: | |
|
Driveway: There are major cracks in the driveway surface. Existing cracks in the driveway could lead to further cracking and erosion. You should consult a qualified contractor about needed repairs. Trees and Shrubs:
Out Buildings: | |
| Exterior and Structure | |
| Exterior Wall Covering: Openings in wall finishes could allow moisture penetration and possible structural damage.( W side) You should contact a qualified Handyman for needed repairs.
Eaves and Soffits:
Windows:
Gutters and Downspouts: | |
| Roofing Components | |
| Roof Leaks: Damage or deterioration was observed.(mastic around most penetrations) There is evidence of past roof leaks. I recommend further investigation by a licenced professional . | |
| Plumbing Components | |
| Fixtures: The toilet tank is not securely attached to toilet bowl.(bath 1) Faucet handles are missing, broken, or defective.( faucet control not functional,bath 2) You should consult a qualified contractor about needed repairs.
Water Heater: | |
| Electrical | |
| Circuits and Conductors: Junction box covers are missing.( storage room) This is a safety hazard that needs to be corrected immediately.
Outlets, Fixtures, and Switches: | |
| Attic | |
| Attic Ventilation: roof vent damaged (screen and louvers) This problem could lead to moisture penetration and possible structural damage. You should consult a qualified contractor about needed repairs.
Attic Vent Pipes:
Attic Moisture:
Attic Sheathing: | |
| Interior | |
| Ceilings: Damage or deterioration was observed on the ceiling material.(hall bath) You should consult a qualified contractor about needed repairs. Stairs/Railings: | |
SITE GROUNDS GRADING
This inspection is not intended to address or include any geological conditions or site stability information. For information concerning these conditions, a geologist or soils engineer should be consulted. Any reference to grade is limited to only areas around the exterior of the exposed foundation or exterior walls. This inspection is visual in nature and does not attempt to determine drainage performance of the site or the condition of any underground piping, including municipal water and sewer service piping or septic systems. When decks and porches are built close to the ground where no viewing or access is possible, we cannot make accurate opinions. These areas as well as others that are too low to enter, or in some other manner not accessible, are excluded from the inspection and are not addressed in this report. We routinely recommend that inquiry be made with the seller about knowledge of conditions.
Sidewalks/Walkways
Driveway
Type: Concrete
Condition: Needs Maintenance
Problems:
-There are large cracks in the driveway. (back to top)
Comments:
There are major cracks in the driveway surface. Existing cracks in the driveway could lead to further cracking and erosion. You should consult a qualified contractor about needed repairs.
Type: Concrete
Condition: Satisfactory
Problems:
Comments:
These components are functional.
Trees and Shrubs

bedroom window. This is a safety hazard that needs to be corrected immediately.
Out Buildings
Fences
Our inspection of the Exterior grounds includes the surface drainage, grading, some fencing, gates, sidewalks, patios, driveways, and retaining walls adjacent to the structure. The inspection of the exterior of the building includes the cladding, trim, eaves, fascias, decks, porches, downspouts, railings, doors, windows and flashings. Areas hidden from view by finished walls or stored items cannot be judged and are not a part of this inspection. Minor cracks are typical in many foundations and most do not represent a structural problem. If major cracks present along with rotation, we routinely recommend further evaluation be made by a qualified professional structural engineer. The grading of the soil should allow for surface and roof water to flow away from the foundation. All concrete slabs experience some degree of cracking due to shrinkage in the drying process or minor settlement. All items listed are inspected for their proper function, poor installation, excessive wear and general state of repair. Whe
Building Information
Wall Structure
Wall Covering
Gas Meter and Piping
Exterior Windows
Exterior Doors
Foundation
Downspouts
Eaves and Soffits
Columns
The inspection of the roof system includes a visual examination of the surface materials, connections, penetrations and roof drainage systems. We examine the roofing material for damage and deterioration. We examine the roof system for possible leaks, damage and conditions that suggest limited remaining service life. We may offer opinions concerning repair and/or replacement if warranted. Opinions stated herein concerning the roofing material are based on the general condition of the roof system as evidence by our visual inspection. These do not constitute a warranty that the roof is or will remain, free of leaks. All roofing systems require annual maintenance. Failure to perform routine maintenance will usually result in leaks and accelerated deterioration of the roof covering and flashings. When provided, our estimates of the roof's life expectancy are based on the assumption that the roof will be properly maintained during that period. The only way to determine whether a roof is absolutely watertight is to
Roof Style
Roof Covering
Roof Leaks
Gutters and Downspouts
center>
Our Inspection of the plumbing system includes a visual examination of the exposed portions of the domestic water supply, drain waste, vent, gas lines, faucets, fixtures, valves, drains, traps, exposed pipes and fittings. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. The hidden nature of piping prevents inspection of every pipe and joint connection, especially in walls, floors and ceiling voids. A sewer lateral test is necessary to determine the condition of the underground sewer lines. This type of test is beyond the scope of this inspection. Our review of the plumbing system does not include landscape irrigation systems, water wells, on site and/or private water supply systems, off site community water supply systems, or private (septic) waste disposal systems unless specifically noted. A qualified specialist prior to the closing of escrow can perform review of these systems. Our inspection of the water heater includes a visual examination of t
Water Service
Fuel Service
Water Entrance
Waste
Fixtures
Pipes
Drains
Vent Pipes
center>
Our examination of the electrical system includes a visual examination of the exposed and accessible branch circuits, wiring, service panel, over current protection devices, lighting fixtures, switches, and receptacles. Service equipment, proper grounding, wiring methods and bonding are focal points. We inspect for adverse conditions such as lack of grounding and bonding, over-fusing, exposed wiring, open-air wire splices, reverse polarity and defective GFCI's. The hidden nature of the electrical wiring prevents inspection of every length of wire or their connections. Telephone, video, cable, audio, security systems and other low voltage systems were not included in this inspection unless specifically noted. We recommend you have the seller or a specialist demonstrate the serviceability or locations of these systems to you if necessary. Any electrical repairs attempted by anyone other than a licensed electrician should be approached with caution. The power to the entire house should be turned off prior to beg
Service Entrance Cable
Service Line Entrance
Main Panel
Sub Panel
Circuits and Conductors
Outlets, Fixtures, and Switches
Smoke Detectors
Our inspection of the Attic includes a visual examination of the roof framing, plumbing, electrical, and mechanical systems. There are often heating ducts, bathroom vent ducts, electrical wiring, chimneys and appliance vents in the Attic. We examined these systems and components for proper function, unusual wear and general state of repair, leakage, venting and unusual or improper improvements. When low clearances and deep insulation prohibits walking in an unfinished Attic, inspection will be from the access opening only. Vaulted ceilings cannot be inspected.
Attic Access
Attic Ventilation
Roof Frame
Vent Pipes & Flashing
Ceiling Frame
Moisture & Mildew
Attic Insulation
Attic Sheathing
center>
Our inspection of the Interior includes a visual inspection of the readily accessible portions of the walls, ceilings, floors, doors, cabinetry, countertops, steps, stairways, balconies and railings. Please note that a representative sample of the accessible windows and electrical receptacles are inspected. These features are examined for proper function, excessive wear and general state of repair. In some cases, all or portions of these components may not be visible because of furnishings and personal items. In these cases some of the items may not be inspected. The condition of walls behind wall coverings, paneling and furnishings cannot be judged. Only the general condition of visible portions of floors is included in this inspection. As a general rule, cosmetic deficiencies are considered normal wear and tear and are not reported. Determining the source of odors or like conditions is not a part of this inspection. Floor covering damage or stains may be hidden by furniture. The condition of floors underlyi
General Information
Floors
Walls
Ceilings
Entry Doors
Interior Doors (door # 1)
Stairs / Railings
Windows
Our inspection of the bathrooms included a visual examination of the readily accessible portions of the floors, walls, ceilings, cabinets, countertops and plumbing fixtures. Bathrooms are inspected for water drainage, damage, deterioration to floor and walls, proper function of components, active leakage, unusual wear and general state of repair. Bathroom fixtures are run simultaneously to check for adequate water flow and pressure. Fixtures are tested using normal operating controls. Vent fans and their ductwork are tested for their proper operation and examined where visible. Shower pans are visually checked for leakage, but leaks often do not show except when the shower is in actual use. Determining whether shower pans, tub/shower surrounds are watertight is beyond the scope of this inspection. It is very important to maintain all grout and caulking in the bath areas. Very minor imperfections can allow water to get into the wall or floor areas and cause damage. Proper ongoing maintenance will be required i
center>
Bathroom Location
Toilets
Ventilation
Bathtub
Shower Walls
Floor
Receptacles
Sinks
center>
Bathroom Location
Toilets
Ventilation
Condition: Needs Maintenance
Out Building: Observed
Problems:
-There are signs of leakage from the outbuilding's roof.
-The walls are sagging or rotting. (back to top)
Comments:
This component is in need of major repair. You should consult a licensed contractor about the needed repairs.
Condition: Satisfactory
Type: Wood
Problems:
Comments:
This component is functioning properly.
EXTERIOR and STRUCTURE
Year Constructed: 1954
Type: Single
Comments:
single story. 3 bedroom 1 bath
Condition: Satisfactory
Type: Masonry
Comments:
This component is functional.
Condition: Satisfactory
Type: Brick
Problems:
-There are vines growing up the side of the wall.
Comments:
Openings in wall finishes could allow moisture penetration and possible structural damage.( W side) You should contact a qualified Handyman for needed repairs.
Exterior Receptacles
Condition: Satisfactory
Type: Non-GFCI
Problems:
-There are exterior receptacles without GFCI circuits. You should consider upgrading.
Comments:
These components are functional.
Condition: Satisfactory
Problems:
Comments:
This component is functional.
Condition: Needs Maintenance
Problems:
-There are windows that have been painted shut or don't function properly.
Comments:
Window in storage unit not functional ( N window) You should consult a qualified contractor about needed repairs.
Condition: Satisfactory
Type: Wood
Problems:
Comments:
These components are functional.
Condition: Unknown
Type: Not Visible
Problems:
Comments:
DISCLAIMER-The foundation is not accessible for inspection due to construction and style of this home, the exterior grading coming up to the exterior wall surface and not leaving enough of a foundation view(if any) to comment on.The type, style and materials are unknown. It's physical condition is unknown. This inspection cannot determine if there is damage or structural problems.
Condition: Needs Maintenance
Problems:
-There are downspouts missing from the building.
Comments:
There is not a Downspout to divert water away from foundation properly.( front porch )You should contact a qualified Handyman for needed repairs.
Condition: Satisfactory
Problems:
Comments:
Damage or deterioration was observed on eave.( some dry rot various locations)
Condition: Satisfactory
Type: Wood
Problems:
Comments:
These components are functional.
ROOF COMPONENTS
Type: Hip
Comments:
The roof was inspected by walking it.
Shingles: Asphalt
Tiles: Not Applicable
Layers: 1 Layer
Approximate Age: Unknown years
Condition: Satisfactory
Problems:
Comments:
This component is functional.
Leaks: Some
Viewed: Roof Surface

Problems:
-The roof has weather-worn flashing.
Comments:
Damage or deterioration was observed.(mastic around most penetrations) There is evidence of past roof leaks. I recommend further investigation by a licenced professional .
Type: Galvanized,vinyl
Condition: Needs Maintenance
Extensions: No Extensions
Problems:
-The gutters are clogged with debris from overhanging trees.
-There are missing sections of gutters/downspouts.
Comments:
This component is in need of minor repair.
PLUMBING SYSTEM
Type: Public
Condition: Satisfactory
Problems:
Comments:
Condition: Satisfactory
Type: Gas Meter
Meter Location: S side
Shutoff Valve Location: next to meter
Comments:
This component is functional.
Type: Copper
Size: 3/4
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Type: Public
Pipes: Cast Iron
Comments:
This component is functional.
Condition: Needs Maintenance
Problems:
-There are drain traps missing from the drains.
Comments:
The toilet tank is not securely attached to toilet bowl.(bath 1) Faucet handles are missing, broken, or defective.( faucet control not functional,bath 2) You should consult a qualified contractor about needed repairs.
Water Heater
Condition: Needs Maintenance
Fuel Type: Gas
Location: Store room
Capacity: 40 gal
Extension: Present
Relief Valve: Present
Seismic Restraint: Not Applicable
Gas Shutoff: Present
Venting (Air Supply): Present
Expansion Tank (Gas): Not Applicable
Problems:
-There are unsafe flue conditions.
Comments:
Clearance to combustibles is inadequate.( vent where passes thru ceiling should be min. 1" clearance from combustibles) You should consult a licensed contractor about the needed repairs.
Condition: Satisfactory
Material: Copper
Flow Rate: Satisfactory
Problems:
Comments:
These components are functional.
Condition: Satisfactory
Type: Cast Iron
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Type: Cast Iron
Problems:
Comments:
These components are functional.
ELECTRIC
Capacity: 100 Amps
Location: SE exterior
Volts: 240-120 Volts
Condition: Satisfactory
Problems:
Comments:
This component is functional.
Type: Overhead
Condition: Satisfactory
Conductor: Copper
Main Disconnect Location: SE exterior
Wiring: Conductors in Conduit
Problems:
Comments:
This component is functional.
Condition: Needs Maintenance
Volts: 240-120v
Capacity: 100A
Type of Overload Protection: Circuit Breakers
Bonding: Not Determined
Grounding: Grounded
Location: SE exterior
Problems:
-The cables are clamped improperly.
Comments:
Condition: Satisfactory
Volts: 120
Capacity: 100A
Location: Arizona room N wall
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Wiring: Copper 110v-220v
Type of Wiring: Romex (Encased in Plastic)
Outlets
Number
GFCI
Exterior
1
Yes
Garage
No
Kitchen
No
Bathroom
1
Yes
Problems:
-There are wires with cracked or open sections of insulation.
Comments:
Junction box covers are missing.( storage room)
This is a safety hazard that needs to be corrected immediately.
Number Tested: All Visible
Method of Testing: Sniffer,plug in tester
Condition: Needs Maintenance
Outlet Testing:
Reverse Polarity: *N.I.
Non-GFCI: Yes
Ungrounded: Yes
Voltage Drop: No
Problems:
-There are missing or broken faceplates.
-Most receptacles are only 2 wire receptacles.
Comments:
Receptacle outlet covers are missing.(MBR N wall) This is a safety hazard that needs to be corrected immediately.
Condition:
Smoke Detectors: Not Tested
Problems:
*The area was not inspected for smoke detectors near bedrooms.
Comments:
ATTIC
Access Type: Scuttle Hole
Attic Access Location: #2 bedroom
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Type: Roof Vents
Fan Type: None Observed

Problems:
-There are large openings (larger than 1/8 inch) without screens.
Comments:
roof vent damaged (screen and louvers) This problem could lead to moisture penetration and possible structural damage. You should consult a qualified contractor about needed repairs.
Condition:
Type: Rafter Framing
Problems:
Comments:
These components are functional.
Condition: Professional Consultation
Leaks Observed: Visible Leaks
Problems:
Comments:
Mastic is deteriated and cracked. This problem could lead to possible structural damage. You should consult a qualified contractor about needed repairs.
Condition: Satisfactory
Type of Framing: Joist Framing
Problems:
Comments:
These components are functional.
Condition: Professional Consultation
Type: Extensive Signs
Comments:
Evidence of moisture penetration.(attic,various locations) I recommend further investigation by a licenced professional as to the cause.
Condition: Satisfactory
Type: Poured
Location: In Rafters
Average Depth (Inches): 6
Problems:
Comments:
This component is functional.
Observed: Observed
Condition: Professional Consultation
Problems:
-There are signs of leakages on the sheathing.
-There are signs of water damage to the sheathing.
Comments:
There are signs of water damage which could indicate that the roof sheathing has problems with leakages.(various locations) I recommend further investigation by a licenced professional as to the cause.
INTERIOR
Number of Bathrooms: 2
Number of Bedrooms: 3
Comments:
Condition: Satisfactory
Type of floor: concrete sealed
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Type: Plaster
Problems:
Comments:
These components are functional.
Condition: Needs Maintenance
Type: Plaster
Problems:
-There are cracks or loose sections in the ceiling.
-There is evidence of water damage to the ceiling.
Comments:
Damage or deterioration was observed on the ceiling material.(hall bath) You should consult a qualified contractor about needed repairs.
Condition: Satisfactory
Material: Wood
Insulation:
Problems:
Comments:
This component is functional.
Location: all interior doors
Condition: Satisfactory
Problems:
Comments:
These components are functional.
Condition: Needs Maintenance
Problems:
*The area was not inspected for an insufficiently lighted stairway.
Comments:
The handrail is loose., dry rot observed hand rail/fence at front porch. You should consult a qualified contractor about needed repairs.
Condition: Satisfactory
Type: Casement
Material: Metal
Glass: Insulated Glass
Storm Windows: No
Problems:
Comments:
The sash hardware for the window is damaged, defective, or missing.(several windows missing cranks)
BATHROOMS
BATHROOM 1
Location:
Location: Main hall
Comments:
Condition: Satisfactory
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Fan Vents To: window
Problems:
Comments:
This component is functional.
Condition: Needs Maintenance
Type: Built-In
Problems:
Comments:
drain stopper is missing.
Condition: Satisfactory
Type: Ceramic Tile
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Type: concrete
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Type: GFCI
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Problems:
Comments:
This component is functional.
BATHROOM 2
Location:
Location: East utility area
Comments:
Condition: Satisfactory
Problems:
Comments:
This component is functional.
Condition: Satisfactory
Fan Vents To: window
Problems:
*The bathroom was not inspected for a working fan for ventilation.
*The bathroom fan was not inspected for vents terminating inside the house.
Comments:
This component is functional.